Explosion-proof IP camera for local network connection VNG-2.../LS (CCA-VIDEOIP)
PURPOSE AND SCOPE OF APPLICATIONExplosion-proof IP camera VNG-2.../LS is intended for arrangement of video surveillance and transmission of video through LAN/WAN/Internet network in hazardous areas at chemical, oil processing, gas and other industrial facilities with potentially explosive atmosphere. No special devices an personal computer are required for operation of the explosion-proof IP camera. Depending on the settings, access to video image obtained by IP camera can be open to all network users or to authorized users only.
Scope of application - hazardous indoor and outdoor areas in accordance with explosion protection marking, GOST 30852.13-2002 (IEC 60079-14:1996) and areas hazardous with combustible dust ignition, as per GOST IEC 61241-3-2011, dangerous production facilities of I, II, III, IV hazard classes under supervision of Rostekhnadzor and national supervisory bodies of the CU and the CIS countries.
Marking:
1Ex db IIC T6...T5 Gb X
1Ex db [op is T6 Ga] IIC T6...T5 Gb X
Ex tb IIIC T80°C...T100°C Db X
Ex tb [op is Da] IIIC T80°C...T100°C Db X
Certificates and permits:
TU 3400-005-72453807-07
TU 26.70.13-044-72453807-2017
Ambient temperature, °С:
-60...+85* (Т5/100°С)
-60...+40 (Т6/80°С)
-60...+85* (Т6/80°С)
* the maximum allowable operating temperature range is indicated. The value depends on the operating temperature of the components.
Supply voltage:
~220 V (50/60 Hz)
Thread on two connecting holes:
Consumption current without heating device:
Not more than 0,3А
Consumption current with heating device:
Not more than 1А
Resolution:
640x480/ 30 frames per second or 320x240/ 30 frames per second
Minimum illuminance:
Color - 3 lx
Network:
Network type: Ethernet, Fast Ethernet; transmission rate: 10/100Mbit/s; remote access protocols: FTP, HTTP, SNTP; supported standards: IEEE 802.3 (Ethernet), IEEE 802.3u (Fast Ethernet)
Electric shock hazard protection class:
I
Climatic version:
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1, W5)
OVERALL AND MOUNTING DIMENSIONS
OPTIONS, ACCESSORIES AND VERSIONS
ORDER CREATION
Device for protection against lightning discharge and high-voltage impulses interference
/ZIP
Heating for automation
/OBOGREV
Protective canopy
/KOZYRJOK
Installation on frame
/RAMA
Drain plug for condensate removal
/DKUV
Anti-condensation coating
/AP
Version for tropics with protection against bugs
/TERMITY
FORMATION OF ORDER
VNG-2 |
- |
Х |
/LS/ |
Х |
– TU 3400-005-72453807-07 |
|
|
|
|
|
|
|
|
|
|
|
Device type
|
|
|
|
|
|
Number and dimension type of cable glands |
|
|
|
|
|
Options, accessories and versions |
EXAMPLE: VNG-2-2KNV/LS-TU 3400-005-72453807-07
GOST R IEC 60079-0-2011, GOST 14254-96 (IEC 529-89), GOST 30852.0-2002 (IEC 60079-0:1998), GOST 30852.1-2002 (IEC 60079-1:1998), GOST 24754-2013, Ch. 7.3 PUE, Ch. 7.4 PUE, TR CU 012/2011, GOST 12.2.007.0-75. OSSS, GOST 30852.20-2002, GOST R IEC 60079-31-2010