Explosion-proof video camera with analog output VNG-2 (CCA-VIDEO)
PURPOSE AND SCOPE OF APPLICATION Explosion-proof camera is intended for video surveillance in hazardous areas of all classes. The camera can be equipped with various lens. The camera can be used for outdoor video surveillance systems if lens with auto iris and thermal housing with heating are selected. The camera is sensitive in IR range.
Scope of application - hazardous indoor and outdoor areas and mines non-hazardous with gas and dust in accordance with explosion protection marking, GOST 30852.13-2002 (IEC 60079-14:1996) that regulates application of the electrical equipment in hazardous and non-hazardous areas at dangerous production facilities of I, II, III, IV hazard classes under supervision of Rostekhnadzor and national supervisory bodies of the CIS countries.
Function switches:
1. Backlight compensation BLC - OFF/ON
2. Automatic gain control AGC - NORMAL/MAX
3. Gamma correction - 0,45/1
Marking:
1Ex db IIC T6...T5 Gb X
1Ex db [op is T6 Ga] IIC T6...T5 Gb X
Ex tb IIIC T80°C...T100°C Db X
Ex tb [op is Da] IIIC T80°C...T100°C Db X
Certificates and permits:
TU 3400-005-72453807-07
TU 26.70.13-044-72453807-2017
Ambient temperature, °С:
-60...+85* (Т5/100°С)
-60...+40 (Т6/80°С)
-60...+85* (Т6/80°С)
*The maximum allowable operating temperature range is indicated. The value depends on the operating temperature of the components used.
Supply voltage:
~220 V (50/60 Hz)
Thread on two connecting holes:
Consumption current without heating device:
not more than 0,3А
Consumption current with heating device:
Not more than 1А
Resolution:
more than 600 TVL
Minimum illuminance:
Color - 0,02 lx/F1.2
Electric shock hazard protection class:
I
Climatic version:
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1, W5)
OVERALL AND MOUNTING DIMENSIONS
OPTIONS, ACCESSORIES AND VERSIONS
ORDER CREATION
Heating for automation
/OBOGREV
Protective canopy
/KOZYRJOK
Installation on frame
/RAMA
Drain plug for condensate removal
/DKUV
Anti-condensation coating
/AP
Version for tropics with protection against bugs
/TERMITY
Device for protection against lightning discharge and high-voltage impulses interference
/ZIP
FORMATION OF ORDER
VNG-2 |
- |
Х |
/ |
Х |
– ТУ 3400-005-72453807-07 |
|
|
|
|
|
|
|
|
|
|
|
Device type
|
|
|
|
|
|
Number and dimension type of cable glands
|
|
|
|
|
|
Options, accessories and versions
|
EXAMPLE: VNG-2-2KNV-TU 3400-005-72453807-07
GOST R IEC 60079-0-2011, GOST 14254-96 (IEC 529-89), GOST 30852.0-2002 (IEC 60079-0:1998), GOST 30852.1-2002 (IEC 60079-1:1998), GOST 24754-2013, Ch. 7.3 PUE, Ch. 7.4 PUE, TR CU 012/2011, GOST 12.2.007.0-75. OSSS, RD 5.2-093-2004, GOST 30852.20-2002, GOST R IEC 60079-31-2010