Drain and breather plugs DKUE (ECD/EXE)

+
x
<
>
Drain and breather plugs DKUE (ECD/EXE)PURPOSE AND SCOPE OF APPLICATION

DKUE breather plugs are used as part of explosion-proof electrical equipment, where condensate drainage and release of gases are required.

DKUE breather plugs combine two functions: condensate draining and correction of atmospheric pressure fluctuations. It is installed in the bottom part of the enclosure and prevents accumulation of moist in the enclosure during seasonal and in-process temperature changes.

DKUE devices are manufactured with a built-in filter which prevents penetration of dust into enclosure. Special grooves in thread and serrated locknut enable quality and safe draining and entirely remove condensate that accumulates on the bottom of the enclosure.

Scope of application – outdoor and indoor hazardous areas as per explosion protection marking, GOST 30852.13-2002 (IEC 60079-14:1996), dangerous production facilities of I, II, III, IV hazard class supervised by Rostechnadzor of the RF and national technical supervision bodies of the Customs Union and CIS countries.

+
CONFORMITY TO STANDARDS IN RUSSIA
ГОСТ Р МЭК 60079-0-2011, ГОСТ 14254-96 (МЭК 529-89), ГОСТ 30852.0-2002 (МЭК 60079-0:1998), ГОСТ 30852.8-2002 (МЭК 60079-0:1998), Гл. 7.3 ПУЭ, Гл. 7.4 ПУЭ, ТР ТС 012/2011
+
CERTIFICATES
Маркировка взрывозащиты Marking:
1Ex e IIC Gb
Ex tb IIIC Db
Ex e IIC Gb U
Ex tb IIIC Db U
Mining equipment marking:
РП Ex e I Mc
Ex e I Mc U
Protection:
+
TECHNICAL DATA
Ambient temperature, °С:
-60...+150
Material:
Nickel-plated brass OT58
Mass, kg:
0,1
Climatic version:
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1, W5)
+
DIMENSIONS, OPTIONS, ACCESSORIES
MARKING
Marine version
/MORE
+
OVERALL AND MOUNTING DIMENSIONS
Габаритные и присоединительные размеры ДКУЕ
+
FORMATION OF MARKING

Example: DKUE TU 3400-007-72453807-07

+
Principle of operation of drain and breather plug DKUE

Принцип работы дренажного и вентиляционного клапана ДКУЕ
+