Explosion-proof flexible three-phase constant wattage heating cable GTG-KABEL3 (RETO-CORD/RD3)

+
x
<
>
Explosion-proof flexible three-phase constant wattage heating cable GTG-KABEL3 (RETO-CORD/RD3)PURPOSE AND SCOPE OF APPLICATION

Explosion-proof flexible heating cable of constant power is intended for heating and maintaining the process temperature of automation objects, tanks, pipelines and any other objects that require additional protection against freezing and icing.

A parallel heating element is located inside the constant wattage heating cable. The heating element consists of a high resistance alloy heating coil wrapped around three parallel conductors. The distance between the points of contact of the conductors determines the length of the heating zone. The parallel design allows you to cut the cable into pieces of the required length and terminate the cable directly on site. As the temperature rises, the output power of the heating cable decreases. The cable's relatively flat temperature curve provides relatively low inrush current and high power output at elevated temperatures.

The explosion-proof three-phase constant watt heating cable provides constant power output along the entire length of the heating surface. The three-phase heating cable is used at low temperatures to maintain the set temperature. The cable can be used in hazardous areas.

For better transfer of heat energy, it is recommended to use PG-TERMOKLEY assembly sealant.

1. Live copper tinned conductors.
2. Insulation.
3. Nichrome wire.
4. Internal insulation.
5. External insulation.
6. Aluminium-magnesium alloy protective braid.
7. Outer protective shell.

Scope of application - explosion hazardous areas of premises and outdoor installations, in accordance with the assigned explosion protection marking, the requirements of GOST IEC 60079-14-2013 and industry safety rules governing the use of this equipment in hazardous areas.

+
CONFORMITY TO STANDARDS IN RUSSIA
ГОСТ 14254-96 (МЭК 529-89), ГОСТ 30852.0-2002 (МЭК 60079-0:1998), ГОСТ Р МЭК 62086-1-2003, ГОСТ 30852.8-2002 (МЭК 60079-0:1998), ТР ТС 012/2011, ТР ТС 004/2011, ГОСТ IEC 61241-1-1-2011, ГОСТ 24754-2013, Гл. 7.3 ПУЭ, Гл. 7.4 ПУЭ, ГОСТ 30852.20-2002, ГОСТ Р МЭК 60079-31-2010
+
CERTIFICATES
Маркировка взрывозащиты Marking:
1Ex e IIС Т5…T3 Gb X
Ex tb IIIC Т95°С…T185°С Db X
Protection:
+
TECHNICAL DATA
Ambient temperature, °С:
-60...+60
Supply voltage, V:
~400
Power, W:
15, 30, 40, 60
Operating position in space:
Any
Climatic version:
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1, W5)
+
DIMENSIONS, OPTIONS, ACCESSORIES
MARKING
Cable element for heating cable end termination
/GTG-ZGK
Non-explosion-proof version
/PROM
+
OVERALL AND MOUNTING DIMENSIONS
Technical data for heating cables type GTG-KABEL3
Type GTG-KABEL3-90-15 GTG-KABEL3-120-30 GTG-KABEL3-150-40 GTG-KABEL3-180-60
Power, W/m 15±10% 30±10% 40±10% 60±10%
Maximum maintained temperature, °C +(90±5) +(120±10) +(150±10) +(180±10)
Maximum allowable temperature without load (1000 hours in total) +205 +205 +205 +205
Nominal cable size, mm 6,4х11,4 6,4х11,4 6,4х11,4 6,4х11,4
Maximum length of heating section at ambient temperature -20°C, m 1 1 1 1
Temperature class Т5/Т95°C Т4/Т125°C Т3/Т155°C Т3/Т155°C
Cable sheath material Fluorinated ethylene propylene Fluorinated ethylene propylene Fluorinated ethylene propylene Fluorinated ethylene propylene
Minimum installation temperature, °C -60 -60 -60 -60
Maximum circuit length when using type "C" circuit breakers in accordance with EN 60898 at 230V
Dimensions of electrical protection installation ТSwitch-on temperature, °C Maximum heating cable length per circuit (m) at 400V AC
GTG-KABEL3-90-15 GTG-KABEL3-120-30 GTG-KABEL3-150-40 GTG-KABEL3-180-60
16A (-20°C) 700 320 240 150
(+10°C) 700 320 240 150
25A (-20°C) 1100 525 390 250
(+10°C) 1100 525 390 250
32A (-20°C) 1400 681 500 320
(+10°C) 1400 681 500 320
40A (-20°C) 1780 858 630 410
(+10°C) 1780 858 630 410

Diagram of dependence of linear power on temperature

+
FORMATION OF MARKING
GTG-KABEL3   Х   Х   Х   Х  – TU ТУ 28.21.13-041-72453807-2017
                  Type of device
                  Maximum maintained operating temperature t °C: 90, 120, 150, 180
                  Power, W: 15, 30, 40, 60
                  Length in meters
                  Options, accessories and versions

Example: GTG-KABEL3-T120-30-30-TU ТУ 28.21.13-041-72453807-2017

+