Explosion-proof flexible heating high temperature high power self-regulating cable GTG-KABEL1-130 (RETO-CORD/S/R130-S-HG-50W)

+
x
<
>
Explosion-proof flexible heating high temperature high power self-regulating cable GTG-KABEL1-130 (RETO-CORD/S/R130-S-HG-50W)PURPOSE AND SCOPE OF APPLICATION Взрывозащищенный гибкий греющий высокотемпературный кабель высокой мощности с саморегулировкой температуры ГТГ-КАБЕЛЬ1-130

Explosion-proof flexible heating self-regulating cable is intended for heating and maintaining of process temperature of automation facilities, reservoirs, pipes and other facilities that require additional protection against freezing and icing.

Heating element material shrinks at low temperatures creating lots of carbon current-conducting paths and reducing electrical resistance. When electric current flows via heating element, a thermal energy output occurs.

Heating element material expands in warmer sections of the explosion-proof heating cable, reducing number of current-conducting paths. Electrical resistance of heating element material increases, resulting in a significant thermal energy output reduction.

Expansion of material of heating element in hot spots of the heating cable almost entirely tears current-conducting paths. Along with that, electric resistance of material becomes very high, which leads to significant reduction of heat energy output.

Взрывозащищенный гибкий греющий высокотемпературный кабель высокой мощности с саморегулировкой температуры ГТГ-КАБЕЛЬ1-130

Взрывозащищенный гибкий греющий высокотемпературный кабель высокой мощности с саморегулировкой температуры ГТГ-КАБЕЛЬ1-130

Scope of application - explosion hazardous areas of premises and outdoor installations, in accordance with the assigned explosion protection marking, the requirements of GOST IEC 60079-14-2013 and industry safety rules governing the use of this equipment in hazardous areas.

+
CONFORMITY TO STANDARDS IN RUSSIA
ГОСТ Р МЭК 60079-0-2011, ГОСТ 14254-96 (МЭК 529-89), ГОСТ 30852.0-2002 (МЭК 60079-0:1998), ГОСТ Р МЭК 62086-1-2003, ГОСТ 30852.8-2002 (МЭК 60079-0:1998), ТР ТС 012/2011, ТР ТС 004/2011, ГОСТ IEC 61241-1-1-2011, ГОСТ 24754-2013, Гл. 7.3 ПУЭ, Гл. 7.4 ПУЭ, ГОСТ 30852.20-2002, ГОСТ Р МЭК 60079-31-2010
+
CERTIFICATES
Маркировка взрывозащиты Marking:
1Ex e IIC T3 Gb X
Ex tb IIIC T140°C Db X
Protection:
+
TECHNICAL DATA
Ambient temperature, °С:
-60...+135
Supply voltage, V:
~230
Power, W:
10, 15, 25, 38, 50, 63
Operating position in space:
Any
Climatic version:
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1, W5)
+
DIMENSIONS, OPTIONS, ACCESSORIES
MARKING
Cable element for heating cable end termination
/GTG-ZGK
Non-explosion-proof version
/PROM
+
OVERALL AND MOUNTING DIMENSIONS
Technical data for heating cables type GTG-KABEL1-130
Type GTG-KABEL1-130-10 GTG-KABEL1-130-15 GTG-KABEL1-130-25 GTG-KABEL1-130-38 GTG-KABEL1-130-50 GTG-KABEL1-130-63
Rated power, W/m 10 ±10% 15 ±10% 25 ±10% 38 ±10% 50 ±10% 63 ±10%
Maximum maintained temperature, °C +(135±10) +(135±10) +(135±10) +(135±10) +(135±10) +(135±10)
Maximum allowable temperature without load (1000 hours in total) +230 +230 +230 +230 +230 +230
Minimum installation temperature, °C -60 -60 -60 -60 -60 -60
Nominal cable size, mm 13,3x5,5 13,3x5,5 13,3x5,5 13,3x5,5 13,3x5,5 13,3x5,5
Maximum length of heating section at ambient temperature -20°C, m 100 100 100 100 100 100
Temperature class Т3 Т3 Т3 Т3 Т3 Т3
Cable sheath material Fluorinated ethylene propylene Fluorinated ethylene propylene Fluorinated ethylene propylene Fluorinated ethylene propylene Fluorinated ethylene propylene Fluorinated ethylene propylene
Maximum circuit length when using type "C" circuit breakers in accordance with EN 60898 at 230V
Dimensions of electrical protection installation Switch-on temperature, °C Maximum heating cable length per circuit (m) at 230V AC
GTG-KABEL1-130-10 GTG-KABEL1-130-15 GTG-KABEL1-130-25 GTG-KABEL1-130-38 GTG-KABEL1-130-50 GTG-KABEL1-130-63
16A (-20°C) 105 84 50 40 20 15
(+10°C) 105 84 50 40 20 15
25A (-20°C) 170 137 95 80 35 25
(+10°C) 170 137 95 80 35 25
32A (-20°C) 220 179 125 100 50 30
(+10°C) 220 179 125 100 50 30
40A (-20°C) 275 226 160 120 60 40
(+10°C) 275 226 160 120 60 40
+
FORMATION OF MARKING
GTG-KABEL1   Х   Х   Х   Х  – TU 28.21.13-041-72453807-2017
                  Type of device
                  Maximum maintained operating temperature t °C: 130
                  Power, W: 10, 15, 25, 38, 50, 63
                  Length in meters
                  Options, accessories and versions

Example: GTG-KABEL 1-130-50-60-TU 28.21.13-041-72453807-2017

+
Diagram of dependence of linear power on temperature
Power, W/m
Diagram of dependence of linear power on temperature GTG-KABEL1
Температура трубы, °С

А – GTG-KABEL1-130-63

B – GTG-KABEL1-130-50

C – GTG-KABEL1-130-38

D – GTG-KABEL1-130-25

E – GTG-KABEL1-130-15

F – GTG-KABEL1-130-10

Устройство саморегулирующегося кабеля

Self-regulating cable structure:

1. Current-conducting stranded tin-plated copper cores.

2. Thermoresistive element.

3. Internal insulation for provision of dielectric strength, moisture tightness, protection against impact loads and abrasion, as well as protection against chemical exposure for heat-producing matrix.

4. Outer insulation.

5. Tinned copper protective braid.

6. Fluoropolymer outer protective sheath is applied in conditions of increased humidity as well as under the exposure of organic substances and solvents or other aggressive substances in common areas or in areas classified as hazardous.

+