Explosion-proof LED light fixtures SGU06 are intended for lighting of industrial premises, open production sites and other areas, where explosive atmospheres may be present.
The construction of explosion-proof light fixtures SGU06 consist of one, two or three modules with 15 W (1860 lm), 28 W (3300 lm, 3720 lm), 55 W (6600 lm) or 110 W (13200 lm) power capacity, which are assembled into explosion-proof LED light fixtures with higher power capacity (miltiplies of power of the used modules).
Area of application - outdoor and indoor hazardous areas, as per explosion protection marking - category II for gas subgroup IIA, IIB, IIC, zones 1, 2, zones non-hazardous with gas and dust.
Model | Consumed power, W | Rated voltage, V | Operating voltage range, V | Current consumption, A | Size, mm | Mass, kg | ||
A | B | C | ||||||
SGU06-1860S.../U | 15 | ~220 | 170…270 AC | 0,1 | 247 | 222 | 82 | 2,8 |
⎓220 | 170…270 DC | 0,1 | ||||||
28 | ~220 | 170…270 AC | 0,2…0,1 | |||||
⎓220 | 170…270 DC | 0,2…0,1 |
Model | Consumed power, W | Rated voltage, V | Operating voltage range, V | Current consumption, A | Size, mm | Mass, kg | |||
A | B | C | M | ||||||
SGU06-3720S.../P | 28 | ~220 | 170…270 AC | 0,2…0,1 | 425 | 170 | 78 | 250 | 4,2 |
⎓220 | 170…270 DC | 0,2…0,1 | |||||||
SGU06-6600S.../P |
55 | ~220 | 150…270 AC | 0,4…0,3 | |||||
⎓220 | 150…270 DC | 0,4…0,3 | |||||||
SGU06-13200S.../P | 110 | ~220 | 150…270 AC | 0,8…0,5 | 775 | 170 | 78 | 550 | 6,5 |
⎓220 | 150…270 DC | 0,8…0,5 | |||||||
SGU06-3720S.../R | 28 | ~220 | 170…270 AC | 0,2…0,1 | 425 | 124 | 105 | 250 | 4,1 |
⎓220 | 170…270 DC | 0,2…0,1 | |||||||
SGU06-6600S.../R | 55 | ~220 | 150…270 AC | 0,4…0,3 | |||||
⎓220 | 150…270 DC | 0,4…0,3 | |||||||
SGU06-13200S.../P | 110 | ~220 | 150…270 AC | 0,8…0,5 | 775 | 124 | 105 | 585 | 6,5 |
⎓220 | 150…270 DC | 0,8…0,5 | |||||||
SGU06-3720S.../U | 28 | ~220 | 170…270 AC | 0,2…0,1 | 465 | 124 | 108 | - | 4,3 |
⎓220 | 170…270 DC | 0,2…0,1 | |||||||
SGU06-6600S.../U | 55 | ~220 | 150…270 AC | 0,4…0,3 | |||||
⎓220 | 150…270 DC | 0,4…0,3 | |||||||
SGU06-13200S.../U | 110 | ~220 | 150…270 AC | 0,8…0,5 | 774 | 124 | 112 | - | 7,9 |
⎓220 | 150…270 DC | 0,8…0,5 | |||||||
SGU06-3720S.../T | 28 | ~220 | 170…270 AC | 0,2…0,1 | 425 | 124 | 135 | - | 4,2 |
⎓220 | 170…270 DC | 0,2…0,1 | |||||||
SGU06-6600S.../T | 55 | ~220 | 150…270 AC | 0,4…0,3 | |||||
⎓220 | 150…270 DC | 0,4…0,3 | |||||||
110 | ~220 | 150…270 AC | 0,8…0,5 | 775 | 124 | 135 | - | 6,5 | |
⎓220 | 150…270 DC | 0,8…0,5 |
Model | Consumed power, W | Rated voltage, V | Operating voltage range, V | Current consumption, A | Size, mm | Mass, kg | ||
A | B | C | ||||||
SGU06-7440S.../10/U | 56 | ~220 | 170…270 AC | 0,4…0,3 | 460 | 275 | 225 | 10,4 |
⎓220 | 170…270 DC | 0,4…0,3 | ||||||
SGU06-13200S.../10/U | 110 | ~220 | 150…270 AC | 0,8…0,5 | ||||
⎓220 | 150…270 DC | 0,8…0,5 | ||||||
220 | ~220 | 150…270 AC | 1,5…0,9 | 810 | 275 | 225 | 10,5 | |
⎓220 | 150…270 DC | 1,5…0,9 |
Model | Consumed power, W | Rated voltage, V | Operating voltage range, V | Current consumption, A | Size, mm | Mass, kg | ||
A | B | C | ||||||
SGU06-11160S.../10/U | 84 | ~220 | 170…270 AC | 0,5…0,4 | 460 | 425 | 230 | 15,1 |
⎓220 | 170…270 DC | 0,5…0,4 | ||||||
SGU06-19800S.../10/U | 165 | ~220 | 150…270 AC | 1,2…0,7 | ||||
⎓220 | 150…270 DC | 1,2…0,7 | ||||||
330 | ~220 | 150…270 AC | 2,3…1,3 | 810 | 425 | 230 | 15,5 | |
⎓220 | 150…270 DC | 2,3…1,3 |
Note:
- The /VSUx option applies to the entire model range of the SGU06-...S luminaire with a luminous flux up to 39600 Lm inclusive.
- The MSK-64 option does not apply to luminaires with luminous fluxes of SGU06-13200S, SGU06-26400S, SGU06-39600S.
SGU06 | - | X | - | X | / | X | / | X | - | X | / | X | – TU 27.40.39-027-72453807-2017 |
Device type | |||||||||||||
Luminous flux, lm*.
1 module: 1860S; 3300S; 3720S; 6600S; 13200S 2 modules: 7440S; 13200S; 26400S 3 modules: 11160S; 19800S; 39600S |
|||||||||||||
Power supply: 220AC, 220DC; | |||||||||||||
Angle between modules, deg.: 0 (default); 10; | |||||||||||||
Mounting type: Pipe mounting - T; Suspended mounting - R; Ceiling mounting - P; Universal swivel mounting (suitable for ceiling and wall mounting at an angle) - U; Universal mounting rotated 90° (only for luminous fluxes 13200) - U90; Wall mounting at 45° - S45 (only for luminous fluxes 3720, 6600, 13200 without additional options) | |||||||||||||
Number and size of cable entries | |||||||||||||
Options, accessories, and configurations |
*On request other values are possible 3720-, 6600- or 13200-fold
Example of order: SGU06-19800S-220AC/10/U-1KNV2NNK/R-TU 27.40.39-027-72453807-2017.
CONNECTION IS PERFORMED THROUGH CABLE GLAND
Recommended cable glands:
PHOTOMETRIC CURVES