GTG-VK1 is an effective solution for connection and input of cables of electric heating systems under hear insulation which simplifies installation and excludes damage to heating cable during its input under heat insulation, as well as it splices ends of the heating cable for T-shaped branches. GTG-VK1 are applied for all types of GTG heating accessories and cables of third party manufacturers. The box shall be fastened to the pipe with two metal fastening clamps which ensure reliability of the grounding circuit between the pipe and the enclosure.
Scope of application – outdoor and indoor hazardous areas as per explosion protection marking, GOST 30852.13-2002 (IEC 60079-14:1996), for use in presence of combustible dust, as per GOST IEC 61241-3-2011, dangerous production facilities of I, II, III, IV hazard class supervised by Rostechnadzor and national technical supervision bodies of the Customs Union and CIS countries.
GTG-VK1-Т01 | GTG-VK1-Т02 |
![]() |
![]() |
- enclosure KSRVВ141410; |
- enclosure KSRVВ141410; - terminal block 10 sq. mm. CBD.10-4 pcs.; - cable gland for non-armored cable KNV2, cable diameter-12-18 mm- 2 pcs.; - plug VZK2-1 pc.; - operating current – up to 57А; - operating voltage – up to 800 V. |
GTG-VK1-Т03 | GTG-VK1-Т04 |
![]() |
![]() |
- enclosure KSRVВ111108; - terminal block 2.5 sq. mm. CBD.2-9 pcs.; - cable gland for non-armored cable KNV2, cable diameter-12-18 mm- 1 pc.; - plug VZK2-1 pc.; - operating current – up to 24А; - operating voltage – up to 800 V. |
- enclosure KSRVВ111108; - terminal block 2.5 sq. mm. CBD.2-9 pcs.; - cable gland for non-armored cable KNV2, cable diameter-12-18 mm- 1 pc.; - operating current – up to 24А; - operating voltage – up to 800 V. |
GTG-VK1-Т05 | GTG-VK1-Т06 |
![]() |
![]() |
- enclosure KSRVВ111108; - terminal block 2.5 sq. mm. CBD.2-9 pcs.; - cable gland for non-armored cable KNV2, cable diameter-12-18 mm- 2 pcs.; - plug VZK2-1 pc.; - operating current – up to 24А; - operating voltage – up to 800 V. |
- enclosure KSRVВ141410; - terminal block 10 sq. mm. CBD.10-3 pcs.; - terminal block 10 sq. mm. TE.10/O(ground) -2 pcs.; - cable gland for non-armored cable KNV2, cable diameter-12-18 mm- 1 pc.; - operating current – up to 57А; - operating voltage – up to 800 V. |
GTG-VK1-Т07 | GTG-VK1-Т08 |
![]() |
![]() |
- enclosure KSRVВ141410; - terminal block 6 sq. mm. CBD.6-3 pcs.; - terminal block 6 sq. mm. TE.6/O(ground) -7 pcs.; - cable gland for non-armored cable KNV2, cable diameter-12-18 mm- 3 pcs.; - plug VZK2- 1 pc.; - operating current – up to 41А; - operating voltage – up to 800 V. |
- enclosure KSRVВ141410; - terminal block 10 sq. mm. CBD.10-7 pcs.; - cable gland for non-armored cable KNV2, cable diameter-12-18 mm- 3 pcs.; - plug VZK2- 2 pcs.; - operating current – up to 57А; - operating voltage – up to 800 V. |
GTG-VK1-Т09 | GTG-VK1-Т10 |
![]() |
![]() |
- enclosure KSRV141410; |
- enclosure KSRV141410; |
Attention! The Manufacturer reserves the right to replace the components by components with similar technical characteristics which have conformity certificates.