ZKG-P Polyamide Explosion-Proof Heated Cabinet for I&C
PURPOSE AND SCOPE OF APPLICATION ZKG-P series polyamide explosion-proof heated cabinets for I&C are used for protection of I&C against negative impact of low temperature, precipitation, dirt, dust and other aggressive environmental factors. The cabinets are located on open sites and in unheated rooms for installation of various Ex equipment, as well as enclosures of local control stations and cabinets if their installation in hazardous areas is required.
AGVANTAGES
- Resistant to petroleum products, chemical environment and UV radiation.
- High protection degree against moisture and dust IP66.
- Installation of various types of heating systems - electric heating, water and steam heating.
- Stainless steel hardware.
- 3 types of mount - suspension, on tripod, on pipe.
- Installation of viewing windows upon customer‘s specification.
- Option of installation of lock on the cover.
Area of application: depending in the chosen version and explosion protection marking, the products can be installed in zones 1, 2, 21, 22 and provide explosion protection in explosive mixtures of categories II, III of group IIA, IIB, IIC, IIIA, IIIB, IIIC.
Marking:
C электрообогревомWith electric heating:
1Ex db e IIC T3 Gb (
ГТГ-МОДУЛЬGTG-MODULE)
1Ex e IIC T3 Gb X (
ГТГ-РАДИАТОР2GTG-RADIATOR2)
1Ex e IIC T3 Gb X (
ГТГ-ПЛАСТИНА1GTG-PLASTINA1)
С обогревом водой и паромWith water and steam heating:
II Gb IIC T3 X (
обогрев водой/паром не вышеwater/steam heating not higher than 195°С)
II Gb IIC T4 X (
обогрев водой/паром не вышеwater/steam heating not higher than 130°С)
II Gb IIC T5 X (
обогрев водой/паром не вышеwater/steam heating not higher than 95°С)
II Gb IIC T6 X (
обогрев водой не вышеwater heating not higher than 80°С)
Без обогреваWithout heating:
IIGb
Ex-компонентEx component:
Ex e IIC Gb U
Ex tb IIIC Db U
II Gb IIC или II Gb IIB
Ех-маркировка шкафа приборного формируются с учётом установленных взрывозащищенных комплектующих. Температурный класс и максимальная температура поверхности в маркировке взрывозащиты зависят от температурного класса и максимальной температуры поверхности установленного оборудования.
Ех marking of I&C cabinet is formed taking into account Ex components installed. The temperature class and maximum surface temperature in explosion protection marking depend on the temperature class and maximum surface temperature of the equipment installed.
Certificates and permits:
TU 27.12.23-060-72453807-2019
Ambient temperature, °С:
-60...+85
Maintained temperature inside the cabinet, °С:
-40...+60 (depending on the heating system applied)
Maximum voltage, V:
~400 (50/60 Gz)
Arrangement of cable glands:
As per customer’s specification
Grounding:
2 stainless steel grounding clamps (inner and outer)
Cover fastening:
On hinges, fixation using stainless steel quick-acting clamps
Installation inside enclosure:
2 mounting panels, /SHINA, DIN rail option is possible
Sealing:
Seal in cover groove
Material:
Multi-layer enclosure made of polyamide with antistatic properties resistant to petroleum products, chemical environment and UV radiation Thickness: 35…45 mm
Enclosure fastening:
On pipe, suspension, tripod
Electric shock hazard protection class:
II
Climatic version:
N1…5, F1…5, NF1…5, U1…5, MU1, W1…5
OVERALL AND MOUNTING DIMENSIONS
View without cover
Overall dimensions
Dimension type |
А, mm |
B, mm |
C, mm |
a, mm |
b, mm |
Mass, kg |
ZKG-P514959 |
510 |
490 |
590 |
400 |
366 |
20 |
OPTIONS, ACCESSORIES AND VERSIONS
ORDER CREATION
Window size as per customer’s specification
/O (size)
Water or steam heating
/PAR
Internal ground bus bar
/SHINA Z
Nameplate with inscription as per customer’s specification
/NADPIS "_"
Remark: For option /SHINA Z, bus bars with 2 holes x 16 mm2 and a row of holes 6 mm2 are installed by default (the quantity depends on the bus bar length). Installation of bus bars with different diameter of holes is possible upon customer’s approval.
FORMATION OF ORDER
ZKG-P |
- |
Х |
/ |
Х |
/ |
Х |
– YU 27.12.23-060-72453807-2017 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Device type |
|
|
|
|
|
|
|
Enclosure size code |
|
|
|
|
|
|
|
Type of mount: wall mount - S; pipe - T; rack mount - SH
|
|
|
|
|
|
|
|
Options, accessories and versions |
Example: ZKG-P514959/S/SHINA/OBOGREV-TU 27.12.23-060-72453807-2019
TR CU 012/2011, GOST 14254-2015, GOST 31441.1-2011, GOST 31610.0-2014 (IEC 60079-0:2011), GOST R IEC 60079-7-2012, GOST R IEC 60079-31; GOST 30852.8-2002, GOST IEC 60079-1-2011, GOST 30852.10-2002 (IEC 60079-11:1999), GOST R IEC 60079-18-2012