Explosion-proof transition cable elements are intended for the connection of flat or round electrical wires or optic cables between two enclosures of the explosion-proof equipment, usually between an Exd-enclosure and input Exe enclosure, or between two Exd enclosures. Actual range of operating temperatures is determined by the applied type of the wires or a cable. More detailed information for certain types is provided upon request. Explosion-proof partition nipple-barriers could be manufactured with hook-up wires (conductor), with coaxial cables (coaxial), with optic cables (optic), with flat wires, with clamping screw (bolted) as per the order.
Upon customer‘s request, stranded gas migration preventing heat-resistant hook-up wires "ZAVOD GORELTEX" Co. Ltd. for partition fittings with completely encapsulated internal space.
Scope of application - hazardous indoor and outdoor areas in accordance with explosion protection marking, GOST 30852.13-2002 (IEC 60079-14:1996), dangerous production facilities of I, II, III, IV hazard classes under supervision of Rostekhnadzor and national supervisory bodies of the CU and the CIS countries.
Type of fitting | Diameter, mm |
H, mm | L, mm | L1, mm |
AC, mm | S, mm |
RKNC-ZK | 10 | 35 | 25,5 | 29 | 14 | 16,5 |
12 | 16 | 19 | ||||
16 | 20 | 23,5 | ||||
24 | 28 | 32,5 | ||||
29 | 32 | 37 | ||||
33 | 36 | 42 | ||||
36 | 40 | 46,5 | ||||
38 | 42 | 48,5 | ||||
42 | 45 | 52 |
RKNC-ZK | - | X | X | ( | X | x | Х | ) | Х | – TU 3400-007-72453807-07 | |
Type of the element | |||||||||||
Diameter | |||||||||||
Material | |||||||||||
Number of wires | |||||||||||
Cross-section of the wires | |||||||||||
Length of free wire ends, dm |
EXAMPLE: RKNC-ZK-10N(3x2.5)2 - TU 27.33.13-031-72453807-2017
- Through insulator with cylindrical connection, sealed with compound,
- material stainless steel,
- 3 wires with a cross-section of 2.5 mm,
- length of free wire ends 2 dm.
Non-standard nipple-barriers can be produced as per customer‘s layout