Explosion-proof protective plugs VZKP are used to seal unused cable glands. Protective plugs VZKP are installed in sealing ring of a cable gland.
Scope of application – underground mines and pits hazardous with gas (methane), coal dust; outdoor and indoor hazardous areas as per explosion protection marking, GOST 30852.13-2002 (IEC 60079-14:1996), dangerous production facilities of I, II, III, IV hazard class supervised by Rostechnadzor of the RF and national technical supervision bodies of the Customs Union and CIS countries.
Plug type | d* diameter, mm |
H length, mm |
VZKP01 | 4 | 24 |
VZKP1 | 7,5 | 24 |
VZKP2 | 13,5 | 24 |
VZKP3 | 15,5 | 29 |
VZKP3S | 22 | 29 |
* Manufacturing of bigger sizes is possible
Cable glands | Plugs for cable glands | |
Type | Size | |
FL / FAL / ML / MAL | 01 | VZKP01 |
1 | VZKP1 | |
2 | VZKP2 | |
3 | VZKP3 | |
4 | to be specified when ordering | |
FLS / FALS / MLS / MALS | 01 | VZKP1 |
1 | VZKP2 | |
2 | VZKP3 | |
3 | no | |
4 | no | |
FG / FGA / FGAD / FGF / FGN | 01 | to be specified when ordering |
1 | VZKP1 | |
2 | VZKP2 | |
3 | no | |
4 | to be specified when ordering | |
UNI | 01 | no |
1 | VZKP1 | |
2 | VZKP2 | |
3 | VZKP3S | |
4 | to be specified when ordering |
VZKP | X | X | – TU 27.33.13-031-72453807-2017 | ||
Type of Plug | |||||
Size | |||||
Material: A - Aluminum, N - Stainless steel AISI 304 |
EXAMPLE: VZKP2A-TU 27.33.13-031-72453807-2017