PGS-IT11 (S-INDICATOR) explosion-proof LED sign
PURPOSE AND SCOPE OF APPLICATION
PGS-IT11 explosion-proof LED sign is used as signage, for issuing light alarm signals indoors and on open production sites in hazardous areas to regulate a person‘s behavior under normal conditions and in emergency situations. It is used in fire alarm systems and automatic fire fighting systems. Thanks to LED technologies and low energy consumption, PGS-IT11 may operate for a long period of time using internal emergency power source, installed upon customer’s request.
Full production cycle from foundry patterns to finished products is carried out by explosion-proof equipment plant “ZAVOD GORELTEX” Co. Ltd. in the territory of the Russian Federation.
Scope of application – outdoor and indoor hazardous areas as per explosion protection marking, GOST 30852.13-2002 (IEC 60079-14:1996), areas with presence of combustible dust, as per GOST IEC 61241-3-2011, dangerous production facilities of I, II, III, IV hazard class supervised by Rostechnadzor of the RF and national technical supervision bodies of the Customs Union and CIS countries.
Marking:
1Ex db IIC T6...T5 Gb
1Ex ia IIC T6...T5 Gb (
для исполнений ⎓12 В, ⎓24 В, без опции /АКБfor 12 V, 24 V version, without /AKB option)
Ex tb IIIC T70°С ...T100°С Db
Ex ia IIIC T70°С...T100°С Da (
для исполнений ⎓12 В, ⎓24 В, без опции /АКБfor 12 V, 24 V version, without /AKB option)
Mining equipment marking:
РН1/РН2
Certificates and permits:
TU 3400-005-72453807-07
TU 27.90.20-038-72453807-2017
Ambient temperature, °С:
-60...+60 (Т6/Т85°С)
-60...+85 (Т5/Т100°С)
-20...+40/+60 (in case of /AKB option)
-60...+60 (in case of /АКB/OBOGREV option, version of the storage battery)
-60...+85 (for mine normal and general industrial versions)
Maximum voltage, V:
12, 24; ~220 (50/60 Hz)
Current consumption, A:
0,13 (for ⎓12 V)
0,11 (for ⎓24 V)
0,025 (for ~220 V)
0,16 (for ~220 V for /AKB option)
0,26 (for ~220 V for /AKB/OBORGEV )
Material:
Modified corrosion-resistant aluminum-silicon alloy, resistant to salt spray and other chemical substances, including hydrogen sulfide and hydrochloric acid fumes, salty and acidic mine waters, frictionally intrinsically safe, polycarbonate sign, galvanized steel rod.
Electric shock hazard protection class:
I
Climatic version:
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1, W5)
OVERALL AND MOUNTING DIMENSIONS
VERSION WITH STORAGE BATTERY /AKB
OPTIONS, ACCESSORIES AND VERSIONS
ORDER CREATION
External surface coating as per customer’s specification
/RAL (___)
Non-explosion-proof version
/PROM
Anti-condensation coating
/AP
Nameplate with inscription as per customer’s specification
/NADPIS "_"
Rechargeable battery
/AKB
Conformity to fire safety requirements
/POZHAR
Earthquake-resistant version
/MSK-64
Mine normal execution
/RN
Protective canopy
/KOZYRJOK
Heating for automation
/OBOGREV
Version for nuclear facilities
/MALAJA TECH
Stainless steel chain for cover
/CEPOCHKA
FORMATION OF ORDER
PGS-IT11 |
- |
X |
/ |
Х |
/ |
Х |
- |
Х |
/ |
Х |
– TU 3400-005-72453807-07 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Type of sound alarm |
|
|
|
|
|
|
|
|
|
|
|
Supply voltage: 12V - 12DC; 24V - 24DC; ~220 V - 220AC |
|
|
|
|
|
|
|
|
|
|
|
Sign (or pictogram code as per GOST 12.4.026-2015) |
|
|
|
|
|
|
|
|
|
|
|
Illumination color: Red - К; Yellow- ZH; Green- Z |
|
|
|
|
|
|
|
|
|
|
|
Number and dimension type of cable glands |
|
|
|
|
|
|
|
|
|
|
|
Options, accessories and versions |
Example: PGS-IT11 -220AC/EXIT/Z-KNV1N/АКB-TU 3400-005-72453807-07
GOST 12.2.007.0-75. OSSS, GOST R IEC 60079-0-2011, GOST 14254-96 (IEC 529-89), GOST 30852.0-2002 (IEC 60079-0:1998), GOST R IEC 60079-31-2010, GOST 30852.1-2002 (IEC 60079-1:1998), GOST 30852.10-2002 (IEC 60079-11:1999), GOST IEC 61241-1-1-2011, Ch. 7.3 PUE, Ch. 7.4 PUE, GOST 24754-2013, TR CU 012/2011, GOST 30852.20-2002, GOST IEC 60950-1-2014, GOST 30805.22-2013, GOST CISPR 24-2013, GOST 30804.3.2-2013, GOST 30804.3.3-2013