Explosion-proof round signs PGS-IT34 (CCA-03H-INDICATOR)
PURPOSE AND SCOPE OF APPLICATION
PGS-IT34 explosion-proof sign is used as signage, for giving light alarm signals in hazardous areas in presence of combustible gases and dust to regulate a person‘s behavior under normal conditions and in emergency situations. It is used in fire alarm systems and automatic fire fighting systems.
Explosion-proof sign PGS-IT34 has two modes of lighting: constant and intermittent with frequency of ~1.5Hz (only for incandescent and LED lamps). Lighting mode depends on selection of circuit.
Scope of application - hazardous indoor and outdoor areas in accordance with explosion protection marking, GOST 30852.13-2002 (IEC 60079-14:1996) and areas hazardous with combustible dust ignition, as per GOST IEC 61241-3-2011, dangerous production facilities of I, II, III, IV hazard classes under supervision of Rostekhnadzor and national supervisory bodies of the Customs Union and the CIS countries.
Marking:
1Ex db IIC T6...T4 Gb
Ex tb IIIC T70°С ...T135°С Db
Mining equipment marking:
РН1/РН2
Certificates and permits:
TU 3400-005-72453807-07
TU 27.90.20-038-72453807-2017
Ambient temperature, °С:
-60...+60 (Т6/Т85°С)
-60...+85 (Т5/Т4/Т100°С/Т135°С)
Rated voltage, V:
~ 220 (50/60 Hz) (other voltage upon agreement)
Grounding:
2 stainless steel ground clamps (inner and outer)
Electric diagram:
Connection to three terminals, cross-section 4 mm2
Cover fastening:
Threaded connection
Sealing:
Silicone rubber (in cover groove), silicone sealant
Enclosure material:
Modified corrosion-resistant aluminum-silicon alloy, resistant to salt spray and other chemical substances, including hydrogen sulfide and hydrochloric acid fumes, salty and acidic mine waters, frictionally intrinsically safe. Window - heat resistant impact resistant glass
Enclosure fastening:
4 outer mounting point
Climatic version:
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1, W5)
OVERALL AND MOUNTING DIMENSIONS
OVERALL AND MOUNTING DIMENIONS OF PGS-IT34.../AKB
VERSION WITH STORAGE BATTERY
OPTIONS, ACCESSORIES AND VERSIONS
ORDER CREATION
Protective canopy
/KOZYRJOK
External surface coating as per customer’s specification
/RAL (___)
Rechargeable battery
/AKB
Breather plug for moisture removal
/VKU
Drain plug for condensate removal
/DKUV
Non-explosion-proof version
/PROM
Anti-condensation coating
/AP
Stainless steel version
/N
Nameplate with inscription as per customer’s specification
/NADPIS "_"
Ingress protection degree IP67
/IP67
Compact fluorescent lamp
/LK
Earthquake-resistant version
/MSK-64
Mine normal execution
/RN
FORMATION OF ORDER
PGS-IT34-Х |
- |
X |
/ |
X |
/ |
Х |
/ |
Х |
- |
Х |
/ |
Х |
– TU 3400-005-72453807-07 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Dimension type of the enclosure |
|
|
|
|
|
|
|
|
|
|
|
|
|
Supply voltage: ~220 V - 220AC (other voltage upon request) |
|
|
|
|
|
|
|
|
|
|
|
|
|
Text (or pictogram code as per GOST 12.4.026-2015) |
|
|
|
|
|
|
|
|
|
|
|
|
|
Text color: white - B; red - K; yellow - ZH; green - Z; blue - S; black - CH |
|
|
|
|
|
|
|
|
|
|
|
|
|
Background color: white - B; red - K; yellow - ZH; green - Z; blue - S; black - CH |
|
|
|
|
|
|
|
|
|
|
|
|
|
Number and dimension type of cable glands |
|
|
|
|
|
|
|
|
|
|
|
|
|
Options, accessories and versions |
Example: PGS-IT34-272721-220AC/GASSY/B/К-KOV1N/SC -TU 3400-005-72453807-07
Standard signs*
FIRE |
FIRE |
EXIT |
red letters, black backgroud
|
white letters, red background
|
white letters, green background
|
Example: PGS-IT34-272721-220AC/GASSY/B/К-KOV1N/SC -TU 3400-005-72453807-07
GOST R IEC 60079-0-2011, GOST 12.2.007.0-75. OSSS, GOST 14254-96 (IEC 529-89), GOST 30852.0-2002 (IEC 60079-0:1998), GOST 30852.1-2002 (IEC 60079-1:1998), GOST R IEC 60079-31-2010, GOST IEC 61241-1-1-2011, GOST 24754-2013, Ch. 7.3 PUE, Ch. 7.4 PUE, TR CU 012/2011, GOST 30852.20-2002, GOST IEC 60950-1-2014, GOST 30805.22-2013, GOST CISPR 24-2013, GOST 30804.3.2-2013, GOST 30804.3.3-2013